• Medical

    Click here for information on customer specific products and installations available to our clients.

  • Industrial

    We can offer an in depth understanding of the issues and requirements facing your sector.

  • Alarm Systems

    We design, supply and install both medical and industrial alarm systems for a wide variety of customers.

  • Maintenance

    We provide a planned servicing and equipment monitoring service to all business sectors.

Press & Media

Another large project secured, this time for another repeat client of ours, KD Group (Ireland & UK)


MIPS KD MECHCANICAL TYMON NORTHMedical & Industrial Pipeline Systems – MIPS – Medical and Industrial Pipeline Systems Limited Showcase Page are very proud to announce we have been selected to provide the medical gas systems installation at the new Tymon North Community Nursing Unit development by Glenbeigh Construction.

Working with KD Mechanical, we have completed a number of projects together in a professional manner to ensure client satisfaction every time. MIPS aim to deliver another quality medical gases installation with KD Mechanical at Tymon North.

Over the past number of months MIPS have developed new practices and technologies that allow us to offer great value and service to all of our clients. No matter what size of job; MIPS will design, install, test, commission and maintain medical and laboratory gas installations in a professional and fully compliant manner whilst offering our services at an extremely competitive cost. Looking forward to working with clients old and new throughout 2018


New MIPS Brochure 6th April 2017


mips-catalogue-2017-email

Hazard Warning 24th January 2017


Make sure your gas pipelines are regularly inspected- That old systems are modified to incorporate modern safety features.

Acetylene Pipe

Acetylene Pipe

Recently one of our customers had a serious incident involving acetylene and oxygen pipelines. A fire started in a confined space. The cause of the fire is unknown at this time. The fire ruptured the oxygen line and the escaping oxygen caused the fire to escalate.

The combination of the oxygen and fire created the conditions to form a thermal lance and the acetylene pipe line was cleanly cut. The acetylene and oxygen mixture continued to burn and the fire spread to the floor above.

Oxygen Pipe

Oxygen Pipe

The lack of safety controls such as flash back arresters on the pipe work system and the poor condition of the pipework due to its age allowed the fire to spread.

Luckily the fire was extinguished by the local fire brigade without loss of life or injuries.

We were requested to repair the damage but when we inspected the acetylene line it was in poor condition we could only recommend that it be totally replaced.

This customer did not have a maintenance contract with us. If so, the incident could probably have been avoided as the equipment would have been inspected and pressure tested by one of our trained technician on a regular basis.

Our maintenance contract service offers the following:

We will for a fixed labour charge Inspect your piped gases installation either 2 or 4 times per year.

That inspection will include the following:

  • Pressure test of your pipework to ensure that the pipework is in good condition. We will pressurise the system to 1.25 times its normal operating pressure (for acetylene pipes up to 1.5 bar) so if there are any weaknesses they will show up in this controlled environment.
  • Visually inspect all visible pipelines, gauges. valves, HP flexible hoses, auto drains and associated pipework.
  • Service any equipment such as compressors, vacuum plant, cylinders and manifolds.
  • We will issue a certificate to confirm the maintenance test has been satisfactorily completed.

The contract also includes an all year emergency call out service.

This service is:

  • Free 24/7 telephone assistance and advice service.
  • Guarantee to have one of our fitters on site within 24 hours (there is an extra charge for this).

Dealing with MIPS will give you peace of mind as:

  • We are fully insured to carry out this work
  • We have over 40 years’ experience
  • Our fitters are fully trained
  • We are ISO 2008 company
  • We are members of British Compressed Gases Association (BCGA)

To arrange for a survey inquire about a maintenance proposal please call Christiana on (01) 8250677 or email her at christiana.timi@mips.ie

Read in Full: Hazard Warning 24th January 2017


Press Release 12th January 2017


long-lar

Lar Sheeran

Medical and Industrial Pipeline Systems Ltd ( MIPS) wish to announce that Lar Sheeran is retiring as CEO and that Adrian Gallagher is appointed to the newly created position of Chief Operations Officer.

Adrian joined MIPS in November and officially takes over the management of the business from January 2017.

Lar the founding Director of MIPS started the business over 40 years ago and will remain the Chairman of the Board and will now focus on a R&D role in the company.

adrian-pic-2

Adrian Gallagher

Medical & Industrial Pipeline Systems Limited is the leading specialist in the design, manufacture, installation, commissioning & maintenance of piped gas equipment for the Medical, Industrial, Laboratory, Computer, Pharmaceutical, Educational and Electronic Industries in Ireland.

Adrian has worked at managing director level for many years in a number of different industries including, contract industrial maintenance, used oil refining and oil distribution.

He believes that MIPS has an exciting future and can further build on its strong reputation and industry leading position. Adrian has already started to make changes in the way the company operates including a new stock control and time management system.

To support Adrian vision for the future the board have committed to continue to invest in the business including an integrated computer system and an enlarged and improved van fleet.

Last week two of the company long standing fitting staff Darren O Reilly and Les Fields handed in their notice. They have decided to pursue other interests and the company wishes them well.

The company will keep you informed of future developments, including our new oxygen generator instillations. Alternatively please call me on (01) 8250677 if you have a query now or visit our website www.mips.ie

Read in Full: Press Release 12th January 2017


Press Release August 2016


AREA-VALVE-SERVICE-UNITAREA VALVE SERVICE UNIT (A.V.S.U. Unit)

Medical and Industrial Pipeline Systems Ltd ( MIPS) are proud to announce that they have commenced manufacture of their own Area Valve Service Units at their factory in Dunshaughlin. Co Meath.

Medical & Industrial Pipeline Systems Limited is the leading specialist in the design, manufacture, installation, commissioning & maintenance of piped gas equipment for the Medical, Industrial, Laboratory, Computer, Pharmaceutical, Educational and Electronic Industries in Ireland.

 

In-house manufacturing enables MIPS to the unit they can now tailor the A.V.S.U’s to individual customer requirements.

The company offer a full one year warrants after installation and can provide an ongoing maintenance service.

Thus a customer can engage MIPS to design, install and commission full pressurised gases systems knowing that MIPS have been installing specialised gases equipment for over 40 years.

MIPS are an ISO 9001:2008 company and member of British Compressed Gases Association.

Read in Full : Press Release August 2016


Press Release April 2016


long-Paul-Callan-Estimating

Paul Callan

Paul Callan

Medical and Industrial Pipeline Systems Ltd (MIPS) wish to announce Paul Callan has joined the company in the position of Engineer.

Medical & Industrial Pipeline Systems Limited is the leading specialist in the design, manufacture, installation, commissioning & maintenance of piped gas equipment for the Medical, Industrial, Laboratory, Computer, Pharmaceutical, Educational and Electronic Industries in Ireland.

Paul is joining the design and estimating department as the companies work flow has increased substantially in the last year. Paul has a qualification in Building Services Engineering from DKIT and has previously worked in the pharmaceutical sector.

I am sure you will join with me wising Paul a very successful career with MIPS.

Read in Full : Press Release April 2016